FlexPower ISCAN™

Network Power Systems

8 - 24 managed and controlled outputs
Single and dual voltage configurations

Why specify managed power?                               Learn more about the benefits of remote monitoring.

access4door
  • Products

  • Overview

  • Technical Documents

  • Support

  • Tools & Software


8 Door Managed System Type Current Power Enclosure
ISCAN150-8 single voltage 12A/12V or 6A/24V 150W E2
ISCAN75/75-8 dual voltage FPO 6A/12V & 3A/24V 150W E2
ISCAN150B-8 dual voltage w/B100 4A/12V & 4A/24V 150W E2
16 Door Managed System Type Current Power Enclosure
ISCAN150-16 single voltage 12A/12V or 6A/24V 150W E2
ISCAN150/250-16 dual voltage FPO 12A/12V or 10A/24V 400W E4
ISCAN250B-16 dual voltage w/B100 4A/12V & 8A/24V 250W E4
24 Door Managed System Type Current Power Enclosure
ISCAN250-24 single voltage 20A/12V or 10A/24V 250W E4
ISCAN250B-24 dual voltage with B100 4A/12V and 8A/24V 250W E4
       

Remote Management and Control

  • 8 - 24 supervised relay outputs with multi-configurable modes of operation
  • 8 - 24 auxiliary outputs for powering non-critical devices
  • Remote power / battery monitoring and reporting

Product Specifications

  • Single and dual voltage configurations
  • Large enclosures accommodate system expansion
  • Microprocessor dual rate charger
  • Built in Fire Alarm disconnect with latch mode for Canada
  • Fault detection and reporting to host power and over the network

iSCAN models are remote managed power supply / battery charger systems specifically designed for the access control segment of the lifesafety industry.

iSCAN provides eight to twenty-four activation inputs and eight to twenty-four monitored and controlled relay outputs. The managed inputs are capable of voltage or dry contact activation and the managed outputs are programmable to either of two system voltages (in a dual voltage configuration) , fail-safe, fail-secure, fire alarm over ride, and AC loss over ride for egress lock control.
Each managed output may also be individually activated or deactivated through an embedded browser interface and monitored for voltage and current values via network or internet.
Adjustable trigger points are provided for each output to generate an alert when that output is outside of selected parameters.

Product highlights

  • Remote managed system
  • Email alert for output condition of
    • over/under current
    • over/under voltage
    • Blown Fuse
    • Short circuit
  • Remote on/off output control

Applications

  • Diagnostic supervision of lock health for banks, hospital wards, drug cabinets, high security areas, casinos, etc.
  • Live monitoring of remote or dangerous areas
  • Perform remote battery tests on scheduled / manual basis
  • Supervise locks and devices for over stress
  • Room temperature change trigger for remote sites, freezers, server rooms etc.

Reliability and Safety

  • Lifetime warranty
  • Easily obtainable and replaceable automotive style ATM fuses

Agency Listings

USA
  • UL 294 / UL 603 / UL 864
  • UL 1076 / UL 1481 / UL 2044 / UL 2572
  • FCC Part 15, Subpart B
  • CSFM Approved
CANADA
  • ULC S318 / ULC S319 / ULC S527
  • CSA C22.2 # 107.1 / CSA 22.2 #60950
  • Ontario ESA
agency box

Product Warranty


8 Door Managed Datasheet Install Manual CAD Files Agency
iSCAN150-8 DS IM CAD AG
iSCAN75/75-8 DS IM CAD AG
iSCAN150B-8 DS IM CAD AG
16 Door Managed Datasheet Install Manual CAD Files Agency
iSCAN150-16 DS IM CAD AG
iSCAN150/250-16 DS IM CAD AG
iSCAN250B-16 DS IM CAD AG
24 Door Managed Datasheet Install Manual CAD Files Agency
ISCAN250-24 DS IM CAD AG
ISCAN250B-24 DS IM CAD AG
   

Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software

Excel spreadsheets designed by the LifeSafety Power technical department to aid the installer in required calculations and example configurations of LifeSafety Power equipment when used in commonly found system applications.