Standard VERTX Power
Doors Single Voltage Current/Voltage Enclosure Outputs Backplate Mounting Guide
2 FPO75-D8E1V 6A/12V 14H×12W×4.5D 8 auxiliary V2000
4 FPO75-D8E2V 6A/12V 20H×16W×4.5D 8 auxiliary V1000 and two V100
8 FPO75-D8E4V 6A/12V 24H×20W×4.5D 8 auxiliary V1000 and four V100
16 FPO150-2D8E4V1 12A/12V 24H×20W×4.5D 16 auxiliary V1000 and eight V100
 
   
 
 
 
Doors Dual Voltage
2 FPO75-B100C4E1V 2A/12V and 2A/24V 14H×12W×4.5D 2 lock &
2 auxiliary
V2000
4 FPO75-B100C4D8E2V 2A/12V and 2A/24V 20H×16W×4.5D 4 lock & 8 auxiliary V1000 and two V100
8 FPO150-B100C8D8E4V1 4A/12V and 4A/24V 24H×20W×4.5D 8 lock &
8  auxiliary
V1000 and four V100
16 FPO75/250-2C82D8E4V1 6A/12V and 10A/24V 24H×20W×4.5D 16 lock &
16 auxiliary
V1000 and eight V100
16 FPO150/250-2C82D8E8V 12A/12V and 10A/24V 36H×30W×4.5D 16 lock &
16 auxiliary
V1000 and eight V100
Managed VERTX Power
Doors Dual Voltage
4 FPO75-B100M8NL4E4V 2A/12V and 2A/24V 24H×20W×4.5D 8 managed V1000 and two V100
8 FPO150-B100D8M8NL4E4V1 4A/12V and 4A/24V 24H×20W×4.5D 8 managed &
8 auxiliary
V1000 and four V100
16 FPO150/250-2D82M8NL4E8V 12A/12V and 10A/24V 36H×30W×4.5D 16 managed &
8 auxiliary
V1000 and eight V100
These standard and managed systems are small sample of possible configurations - contact Technical Support for more options
Enclosures
2-4 E2V 20H×16W×4.5D
4-8 E4V 24H×20W×4.5D
8-16 E4V1* 24H×20W×4.5D
8-16 E8V 36H×30W×4.5D
*No battery space for 16 doors


Integrated Access & Power

  • VCLASS™ all-in-one systems puts power and VertX® panels in one secure locking enclosure
  • One AC drop minimizes wall space, simplifies installation, reduces time & labor costs
  • FlexPower® modularity and VCLASS™ versatility create unlimited system configurations
  • Network options for diagnostic monitoring and control of power, battery and connected devices

Labor Saving Enclosure Design

  • Factory pre-wired power section saves configuration time
  • Removable backplate simplifies controller wiring
  • 4.5" enclosure depth accomodates battery sets
  • Multiple knockout areas along all four sides

System Refinements

  • Fault detection and reporting to host power and over the network with optional NetLink module
  • Large enclosures with room for increased power, added output distribution or remote monitoring
  • Modular power and distribution boards with snap-in standoffs simplify service and field upgrades
  • Cam lock set, tamper switch and backplate hardware to mount the access control panels is included

PRODUCT HIGHLITES

VCLASS™ unified power systems offers maximum flexibility, functionality and savings to access system designers.

VCLASS enclosures are engineered to house FlexPower® power management boards alongside HID VertX® access controllers in one compact, secure system.

To prevent damage to system electronics, the backplate seperates from the enclosure for access hardware mounting in the shop while wiring is pulled to the enclosure at the job site. Once configured, the backplate can be remounted for final ties and checkout.

Features

  • Removable back plate simplifies job installation
  • Engineered backplate pattern minimizes installation time
  • Power boards mount on snap-in stand offs
  • Access boards mount on supplied threaded metal standoffs

Mechanical refinements

  • 4.5" enclosure depth to accommodate battery
  • 19 Gauge steel with textured black finish
  • Board mounting hardware provided
  • Lock and tamper switch standard

Reliability and Safety

  • Lifetime Warranty
  • RoHS Compliant

Agency Listings

  • UL 294 / UL 603
  • UL 1076
  • ULC S318, 319,
  • FCC Part 15, Subpart B
  • CSA C22.2 107.1
  • CSA 22.2 #60950
  • Ontario ESA

agency box

Product Warranty


 VERTX Standard Power
Single Voltage Datasheet Install Manual CAD Files Agency
FPO75-D8E1V DS IM CAD AG
FPO75-D8E2V DS IM CAD AG
FPO75-D8E4V DS IM CAD AG
FPO150-2D8E4V1 DS IM CAD AG
Dual Voltage Datasheet Install Manual CAD Files Agency
FPO75-B100C4E1V DS IM CAD AG
FPO75-B100C4D8E2V DS IM CAD AG
FPO150-B100C8D8E4V1 DS IM CAD AG
FPO75/250-2C82D8E4V1 DS IM CAD AG
FPO150/250-2C82D8E8V DS IM CAD AG
 VERTX Managed Power
Dual Voltage Datasheet Install Manual CAD Files Agency
FPO75-B100M8NL4E4V DS IM CAD AG
FPO150-B100D8M8NL4E4V1 DS IM CAD AG
FPO150/250-2D82M8NL4E8V DS IM CAD AG
 VERTX Enclosures 
E2V DS   CAD  
E4V DS   CAD  
E4V1* DS   CAD  
E8V DS   CAD  

Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software

Excel spreadsheets designed by the LifeSafety Power technical department to aid the installer in required calculations and example configurations of LifeSafety Power equipment when used in commonly found system applications.

Application Notes
AN26_Distribution options