Model # Zone count Current per zone Power limited
C4 4 3A No
C4P 4 2.5A Yes
C8 8 3A No
C8P 8 2.5A Yes
C4 / C8 Fuse protected
C4P / C8P PTC circuit breaker protection, Class 2 Power Limited

Flexibility

  • Simple field selectable switch sets either 12 or 24V DC output
  • FlexConnect system minimizes installation labor by using board buss structure to eliminate accessory board interwiring
  • Configuration jumpers are colored by function for ease of programming
        - FAI

        - INVERT input

        - WET/DRY output

        - V SELECT

      - INVERT output

Expandability

  • Expand number of voltage outputs in increments of eight
  • Add FAI functionality on a per zone basis
  • Add simultaneous failsafe – failsecure voltage outputs
  • Pre-punched cabinet layout allows expansion board additions with minimal labor

C4 and C8 power controller modules provide 4 or 8 relay controlled, protected outputs and 4 or 8 access control inputs. When used in a single voltage system, each individual output may be programmed for a continuous output or to respond to the input from the access control system. A fire alarm interface to over ride the access control system for control of egress locks is provided for each output. When used in a dual voltage system, each individual output zone may be programmed to operate with either of the two system voltages.

Product highlights

  • Listed for Fire Alarm, Intrusion, Access Control, CCTV and Mass Notification
  • Provides 4 or 8 trigger input zones for interface to an access control system
  • Provides 4 or 8 relay controlled output zones
  • Accommodates failsafe or failsecure locking devices
  • Provides fire alarm interface for egress lock control
  • Monitors fuse integrity of output zones and reports fault to host power supply
  • Status LEDs report zone activity
  • Each output zone is fused at 3A or 2.5A for PTC circuit breakers
  • PTC versions are low voltage, Class 2 power limited
  • Allow selection by zone from two voltage sources

Reliability and Safety

  • 10 year warranty
  • Easily obtainable and replaceable automotive style ATM fuses

Agency Listings

USA
  • UL 294 / UL 603 / UL 864
  • UL 1076 / UL 1481 / UL 2044 / UL 2572
  • FCC Part 15, Subpart B
  • CSFM Approved
CANADA
  • ULC S318 / ULC S319 / ULC S527
  • CSA C22.2 # 107.1 / CSA 22.2 #60950
  • Ontario ESA
agency box

Product Warranty


Model # Datasheet Install Manual CAD Files Agency
C4 DS IM CAD AG
C4P DS IM CAD AG
C8 DS IM CAD AG
C8P DS IM CAD AG

Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software

Excel spreadsheets designed by the LifeSafety Power technical department to aid the installer in required calculations and example configurations of LifeSafety Power equipment when used in commonly found system applications.