E1 Enclosure

Power Type Output Size
FPO75-E1 Single Voltage 75W 14x12x4.5
FPO75-B100E1 Dual Voltage 75W 14x12x4.5
FPO75-2B100E1 Triple Voltage 75W 14x12x4.5
FPO150-E1 Single Voltage 150W 14x12x4.5
FPO150-B100E1 Dual Voltage 150W 14x12x4.5
FPO150-2B100E1 Triple Voltage 150W 14x12x4.5
FPO250-E1 Single Voltage 250W 14x12x4.5
FPO250-B100E1 Dual Voltage 250W 14x12x4.5
       

E2 Enclosure

Power Type Output Size
FPO75-E2 Single Voltage 75W 20x16x4.5
FPO75-B100E2 Dual Voltage 75W 20x16x4.5
FPO75/75-E2 Dual Voltage 150W 20x16x4.5
FPO75/150-E2 Dual Voltage 225W 20x16x4.5
FPO75/250-E2 Dual Voltage 325W 20x16x4.5
FPO150-E2 Single Voltage 150W 20x16x4.5
FPO150-B100E2 Dual Voltage 150W 20x16x4.5
FPO150/150-E2 Dual Voltage 300W 20x16x4.5
FPO150/250-E2 Dual Voltage 400W 20x16x4.5
FPO250-E2 Single Voltage 250W 20x16x4.5
FPO250-B100E2 Dual Voltage 250W 20x16x4.5
FPO250/250-E2 Dual Voltage 500W 20x16x4.5
       

E4 Enclosure

Power Type Output Size
FPO75-E4 Single Voltage 75W 24x20x6.5
FPO75-B100E4 Dual Voltage 75W 24x20x6.5
FPO75/75-E4 Dual Voltage 150W 24x20x6.5
FPO75/150-E4 Dual Voltage 225W 24x20x6.5
FPO75/250-E4 Dual Voltage 325W 24x20x6.5
FPO150-E4 Single Voltage 150W 24x20x6.5
FPO150-B100E4 Dual Voltage 150W 24x20x6.5
FPO150/150-E4 Dual Voltage 300W 24x20x6.5
FPO150/250-E4 Dual Voltage 400W 24x20x6.5
FPO250-E4 Single Voltage 250W 24x20x6.5
FPO250-B100E4 Dual Voltage 250W 24x20x6.5
FPO250/250-E4 Dual Voltage 500W 24x20x6.5


System Features
The FlexPower Expandable Power Systems offer single, dual, or multi-voltage power systems housed in various enclosure sizes for simple power requirments or to be expanded with LSP accessory modules in the field.

Listed modular accessories that can be added to any system include: power distribution, relay based lock control, egress lock control, secondary voltage and network connection.

Each FPO power supply provides one pair of outputs, user selectable for 12 or 24 VDC, the unit is configured in a painted, steel, locking enclosure with tamper switch and integral battery space. One output of a pair provides continuous output power for system use, the second is programmable for either fail-safe or fail-secure operation, activated when the fire alarm disconnect is initiated. Models with a B100 provide dual voltage output with a single AC connection.

Complete fault detection and reporting, with programmable fault delays, is provided along with datalogging capability of fault occurrence, battery usage time and current power supply status.

Each FPO power supply provides one pair of outputs, user selectable for 12 or 24 VDC, the unit is configured in a painted, steel, locking enclosure with tamper switch and integral battery space. One output of a pair provides continuous output power for system use, the second is programmable for either fail-safe or fail-secure operation, activated when the fire alarm disconnect is initiated. Models with a B100 provide dual voltage output with a single AC connection.

FlexPower accessory boards can be added to a FlexPower system in ANY combination based on job requirements and system retains its complete agency listing.

Product highlights

  • Fully modular power management system
  • Multiple outputs for system power, direct lock control and accessory power distribution modules
  • Fire alarm interface for egress lock control (FAI)
  • Configurable fail-safe / fail-secure modes of operation
  • Comprehensive fault detection and reporting including optional earth ground and battery presence
  • AC and System fault output relays can be delayed via PowerCom/li>
  • Microprocessor smart charging restores battery sets from 4 to 80 amphours
  • Adding a NetLink module connects power supply to a LAN/WAN network for remote power supply programming and diagnostics. Monitors and reports system status, battery state, generates email or SNMP notification of system trouble or time to service alert

Reliability and Safety

  • Lifetime warranty
  • RoHS Compliant

Agency Listings

  • UL 294 / UL 603 / UL 1076
  • ULC S318, 319
  • FCC Part 15, Subpart B
  • CSA C22.2 #205

Product Warranty

 

Model #

Datasheet Install Manual CAD Files Agency
FPO75-E1 DS IM CAD AG
FPO75-B100E1 DS IM CAD AG
FPO75-2B100E1 DS IM CAD AG
FPO150-E1 DS IM CAD AG
FPO150-B100E1 DS IM CAD AG
FPO150-2B100E1 DS IM CAD AG
FPO250-E1 DS IM CAD AG
FPO250-B100E1 DS IM CAD AG
FPO75-E2 DS IM CAD AG
FPO75-B100E2 DS IM CAD AG
FPO75/75-E2 DS IM CAD AG
FPO75/150-E2 DS IM CAD AG
FPO75/250-E2 DS IM CAD AG
FPO150-E2 DS IM CAD AG
FPO150-B100E2 DS IM CAD AG
FPO150/150-E2 DS IM CAD AG
FPO150/250-E2 DS IM CAD AG
FPO250-E2 DS IM CAD AG
FPO250-B100E2 DS IM CAD AG
FPO250/250-E2 DS IM CAD AG
FPO75-E4 DS IM CAD AG
FPO75-B100E4 DS IM CAD AG
FPO75/75-E4 DS IM CAD AG
FPO75/150-E4 DS IM CAD AG
FPO75/250-E4 DS IM CAD AG
FPO150-E4 DS IM CAD AG
FPO150-B100E4 DS IM CAD AG
FPO150/150-E4 DS IM CAD AG
FPO150/250-E4 DS IM CAD AG
FPO250-E4 DS IM CAD AG
FPO250-B100E4 DS IM CAD AG
FPO250/250-E4 DS IM CAD AG


Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software

Excel spreadsheets designed by the LifeSafety Power technical department to aid the installer in required calculations and example configurations of LifeSafety Power equipment when used in commonly found system applications.