Home Products Network communication System power monitoring
PDF Print E-mail

NetLink Remote Monitoring Modules

Create additional RMR and increase value to the end user.

Use the power of NetLink to create a more secure system by adding the capability to remote monitor the system power, remote test battery sets, generate email SNMP alert messages on a fault, abnormal condition or scheduled service needed, remote control selected devices, and utilize remote diagnostics to reduce tech service time.

White Paper - ROI of Managed Power

White Paper - Why Specify Managed Power

Cyber-security Guidelines

DataLink Communication
 
  • Products

  • Overview

  • Technical Documents

  • Support

  • Tools & Software


Model # Device Support Voltage Meter Current Meter Event
Input
On/Off Control Batteries Managed M8 Compatible
NL2 2 1 1 1 2 1 No
NL4 4 1 2 1 2 2 Yes
NLX 24* 1 4 1 2** 8*** Yes

* NLX monitors 8 local SPI devices and 16 additional Gen2 LSP devices via RS485
** NLX has two on-board relays for controlling aux devices
*** NLX can monitor battery sets on up to eight Gen2 FPO power supplies or up to four Gen1 FPO power supplies

NetLink is a continuously growing and improving family of patented network communication modules from LifeSafety Power that monitor and control LSP's access and security systems over a local or wide area network.

NetLink continuously monitors and reports the health and status of host power supplies and their battery sets, allowing many service functions to be done remotely, reducing the cost and time of on site servicing as well as the difficulty or danger in working restricted areas.

Automated reports may be generated on any detected fault condition, fire alarm input activation, event activation, battery aging condition, or on a time base for scheduled confirmation of proper operation. A time and date stamped log of the past 100 events is kept as history in a buffer and can be accessed as a scheduled report, or immediately on an alert or occurrence.

In addition to multiple SPI ports and RS485 port (NLX only) for connection to FlexPower equipment, the NetLink modules provide a current sensor input(s), a remote temperature sensor input (NL4, NLX), a volt meter input, and a contact monitor input. The contact monitor input can be programmed to respond to either a normally open or normally closed contact or voltage presence or loss.

When used with LifeSafety Power's M8 power monitoring modules, individual output monitoring is added, providing visibility to voltage and current on each device, the ability or remotely power cycle devices, and the ability to receive proactive alerts on impending failures of devices such as locks.

Two outputs are also provided for use in power cycling external equiment.

 


Monitored
Parameters
Programmable
Functions
Event-triggered
Alerts & Reports
Power Supply output voltage AC fault delay AC fault occurrence
AC fault status System fault delay System fault occurrence
System fault status System install date FAI activation occurrrence
Fire alarm input status Reset fault counters Low battery occurrence
Battery voltage Optimal charging current Battery load test comepleted
Battery charge current Reset battery age counter General system status report
Battery age Battery replacement period Scheduled service due alert
System fault count   Battery replacement due alert
AC fault count Control Functions Event activation (user specified)
DC current (via current input) Output 1 (on or off) Temperature out of range
DC voltage (via voltage input) Output 2 (on or off)

Voltage out of range

Event 1 (user specified)   Current out of range
AC input voltage (FPO Gen2 Only) Test Functions  
  Battery load, w/ system as load  
  Battery state  

Model # Datasheet Install Manual CAD Files Agency
NL2 DS IM CAD AG
NL4 DS IM CAD AG
NLX DS IM CAD AG

Troubleshooting Guide Factory Contact Business Contact
FPO Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Accessory Troubleshooting This e-mail address is being protected from spambots. You need JavaScript enabled to view it Area Sales Representatives

Tools & Software

Excel spreadsheets designed by the LifeSafety Power technical department to aid the installer in required calculations and example configurations of LifeSafety Power equipment when used in commonly found system applications.