Product Features:
Agency Listings:
USA
Canada
System Features:
Single voltage systems are user selectable for either 12 or 24VDC. Dual voltage systems are user selectable on each of the two provided power supplies. Available with either fused or power limited outputs - see datasheet for proper model number.
These preconfigured access power systems have relay controlled outputs individually programmable to failsafe, failsecure, dry contact, continuous voltage output, and fire alarm interface for egress lock control.
Need help selecting a product? Try our Product Selector and drag and drop Configurator!
Model | PS 1 Current/Voltage | PS 2 Current/Voltage | Full Control | Aux Output | FAI Output | Data Sheet | Install Manuals | CAD Files |
FPO75-C4E1 | 6A/12 or 3A/24 | 4 | CAD | |||||
FPO150-C4E1 | 12A/12 or 6A/24 | 4 | CAD | |||||
FPO75/75-C4D8E1 | 6A/12 or 3A/24 | 6A/12 or 3A/24 | 4 | 8 | CAD | |||
FPO75/150-C4D8E1 | 6A/12 or 3A/24 | 12A/12 or 6A/24 | 4 | 8 | CAD | |||
FPO75-B100C4D8E1 | 2A/24* | 2A/12* | 4 | 8 | CAD |
*To calculate system loading with a FPO/B100 see App Note AN07.
Model | PS 1 Current/Voltage | PS 2 Current/Voltage | Full Control | Aux Output | FAI Output | Data Sheet | Install Manuals | CAD Files |
FPO75-C8E1 | 6A/12 or 3A/24 | 8 | CAD | |||||
FPO150-C8E1 | 12A/12 or 6A/24 | 8 | CAD | |||||
FPO250-C8E1 | 20A/12 or 10A/24 | 8 | CAD | |||||
FPO150-C8D8E2 | 12A/12 or 6A/24 | 8 | 8 | CAD | ||||
FPO250-C8D8E2 | 20A/12 or 10A/24 | 8 | 8 | CAD | ||||
FPO75/75-C8D8E2 | 6A/12 or 3A/24 | 6A/12 or 3A/24 | 8 | 8 | CAD | |||
FPO75/150-C8D8E2 | 6A/12 or 3A/24 | 12A/12 or 6A/24 | 8 | 8 | CAD | |||
FPO150/150-C8D8E2 | 12A/12 or 6A/24 | 12A/12 or 6A/24 | 8 | 8 | CAD | |||
FPO150/250-C8D8E2 | 12A/12 or 6A/24 | 20A/12 or 10A/24 | 8 | 8 | CAD | |||
FPO250/250-C8D8E2 | 20A/12 or 10A/24 | 20A/12 or 10A/24 | 8 | 8 | CAD | |||
FPO150-B100C8D8E2 | 4A/24* | 4A/12* | 8 | 8 | CAD | |||
FPO250-B100C8D8E2 | 8A/24* | 4A/12* | 8 | 8 | CAD | |||
FPO75-F8PE1 | 6A/12 or 3A/24 | 8 (F8 control) | CAD | |||||
FPO150-F8PE1 | 12A/12 or 6A/24 | 8 (F8 control) | CAD | |||||
FPO250-F8PE1 | 20A/12 or 10A/24 | 8 (F8 control) | CAD |
*To calculate system loading with a FPO/B100 see App Note AN07.
Model | PS 1 Current/Voltage | PS 2 Current/Voltage | Full Control | Aux Output | FAI Output | Data Sheet | Install Manuals | CAD Files |
FPO150-2C82D8E4 | 12A/12 or 6A/24 | 16 | 16 | CAD | ||||
FPO250-2C82D8E4 | 20A/12 or 10A/24 | 16 | 16 | CAD | ||||
FPO75/75-2C82D8E4 | 6A/12 or 3A/24 | 6A/12 or 3A/24 | 16 | 16 | CAD | |||
FPO150/150-2C82D8E4 | 12A/12 or 6A/24 | 12A/12 or 6A/24 | 16 | 16 | CAD | |||
FPO150/250-2C82D8E4 | 12A/12 or 6A/24 | 20A/12 or 10A/24 | 16 | 16 | CAD | |||
FPO250/250-2C82D8E4 | 20A/12 or 10A/24 | 20A/12 or 10A/24 | 16 | 16 | CAD | |||
FPO150-B1002C82D8E4 | 4A/24* | 4A/12* | 16 | 16 | CAD | |||
FPO250-B1002C82D8E4 | 8A/24* | 4A/12* | 16 | 16 | CAD | |||
FPO250-2F8PE1 | 20A/12 or 10A/24 | 16 (F8 control) | CAD |